Licensed & insured Free on-site estimates Same-week scheduling Hillsborough County & Pasco
Call 813-565-3194

Costs

How Much Does Pool Cage Rescreening Cost in Tampa?

Single-story cages run $1,100 to $2,000. Two-story cages run $1,900 to $3,400. Here is what actually moves your number, and the five things a suspiciously cheap quote is usually leaving out.

The reason nobody publishes screen prices is that it makes quotes comparable, and comparable quotes compress margins. We publish them anyway, because the alternative is a market where homeowners have no way to tell a fair number from a padded one.

The short answer

ItemDetail
Single wall panel$35 – $65
Roof or gable panel$55 – $95
Full cage, one story$1,100 – $2,000
Full cage, two story$1,900 – $3,400
Florida Glass kick plate$70 – $130 each
Pet mesh upgrade+$1.75 – $3.25 per sq ft

Those are Tampa-area numbers as of mid-2026 for a competent job using UV-stable mesh and new spline. If you are quoted meaningfully below the bottom of those ranges, something is being left out, and the rest of this article is about identifying what.

The five things that actually move the price

1. Panel count, not square footage

Rescreening is priced per opening rather than per square foot, because the labour is in the cutting, splining and tensioning of each panel rather than in the mesh itself. A cage with eighteen large panels costs less to rescreen than one with thirty small panels covering the same area. Count your panels before you call and you will understand your own quote considerably better.

Technician rescreening a large two-story pool cage panel in Tampa

2. Height and access

This is the single biggest jump in the pricing. A two-story cage costs roughly seventy percent more than a single-story one with a similar panel count, because everything above the first level requires ladders or staging, takes longer, and carries more risk. Roof panels on a steeply pitched cage are the most expensive openings on the structure.

3. Mesh grade

Standard charcoal 18×14 fiberglass is the baseline. No-see-um 20×20 adds modestly. Pet-resistant polyester adds $1.75 to $3.25 per square foot, which on a full cage can mean $600 to $1,400. Florida Glass is priced per panel. Choosing mesh selectively rather than uniformly is the easiest way to control this line.

4. Frame condition

Roughly one in four Tampa cages needs aluminum work before rescreening. Fasteners that no longer bite, corrosion spreading from screw points, pulled anchors, opened corner joints. That is $110 to $700 depending on what is wrong, and it is not optional — mesh tensioned into a failing frame goes slack within a season.

5. Whether the roof screens are included

Pool enclosure being measured and panels counted for a rescreening estimate

This is where cheap quotes hide. Roof and gable panels take the most direct UV and fail first, and they are also the most expensive and awkward to replace. A quote that covers wall panels only can look thirty percent cheaper while leaving you with the worst panels untouched.

How to compare two quotes properlyAsk both companies for the panel count they are pricing, whether roof screens are included, what mesh grade and weave, whether spline is new or reused, and what they found on the frame. Any quote that cannot answer all five is not really a quote.

What a suspiciously cheap quote usually means

  • Reused spline. The single most common shortcut. Old spline is dried and shrunken, so the mesh goes slack within a year. New spline costs very little and takes no extra time — reusing it is purely about speed.
  • Roof panels excluded. Quietly quoting walls only, on the panels that needed it least.
  • Cheaper mesh grade. Economy fiberglass rather than UV-stable, which in Tampa sun means three years instead of six.
  • Frame problems ignored. Not mentioned at the estimate, and not your problem until the panels sag.
  • Mesh grain run wrong. Screen has a direction. Run it the wrong way to save cutting waste and the panel bags out in the middle within months.

Is a full rescreen or partial the better value?

Judge by the condition of the panels you were not planning to touch. If the undamaged mesh is still dark and springy, replace only what has failed. If it is grey and tears when pressed, you will be back within two years and paying mobilisation twice. On unshaded Tampa lots the south and west walls commonly fail first, and doing those two walls now and the rest later is a legitimate way to spread cost — accepting that new mesh looks noticeably darker beside sun-faded panels.

What we would tell you on your deck

If your mesh has three or four good years left, we say so and quote only the damaged panels. If you have dogs, we recommend pet mesh on the lower rows rather than the whole cage. If the frame is the real issue, we quote frame repair first and tell you plainly that new screen on bad aluminum is money thrown away. Full pricing detail is on our pool cage rescreening page.

Need this looked at? Free on-site estimate anywhere in our service area, with a flat written price before we start. Call 813-565-3194 or request a quote.

Questions

Related questions

Single-story enclosures average $1,100 to $2,000 and two-story cages $1,900 to $3,400. The single biggest variables are panel count and height. Individual panels are $35 to $65 when you only need a few, and roof or gable panels run $55 to $95 because of the access.

Roughly seventy percent more for a similar panel count, because everything above the first level needs ladders or staging. It takes longer, carries more risk, and roof panels on a pitched cage are the most awkward openings on the structure. It is a real cost difference rather than a surcharge.

Rescreening is dramatically cheaper as long as the aluminum is sound, since frames outlast mesh by decades when they are not corroded through. Replacement only makes sense when most uprights are compromised, the footer has failed, or the cage was undersized for current wind code.

Ask five questions: what panel count are you pricing, are roof screens included, what mesh grade and weave, is spline new or reused, and what did you find on the frame. Cheap quotes almost always fail on reused spline or excluded roof panels.

Standard charcoal 18x14 fiberglass is the baseline. No-see-um adds modestly. Pet-resistant polyester adds $1.75 to $3.25 per square foot, which is $600 to $1,400 on a full cage. Choosing mesh selectively — pet mesh only on lower rows, no-see-um only on affected walls — controls this line far better than choosing uniformly.

Yes, but make them comparable first. Two quotes that price different panel counts, different mesh grades and different scopes are not comparable numbers. Get the panel count in writing from each company and confirm whether roof screens are in or out.

No, and no deposit is required. We measure every opening, count panels, check spline and frame condition, and hand you a flat written price. If you decide not to proceed you owe nothing. There is no honest way to price a screen job from a phone description alone.

One day for a standard single-story cage, two days for two-story enclosures or any cage that also needs frame repair. Rushing the tensioning step is exactly how a rescreen ends up sagging by August, so we schedule realistically rather than promising same-day on a thirty-panel cage.

Get your screens fixed right

Free on-site estimate, flat written price, and a crew that does nothing but screens. Tell us what's torn and we'll tell you what it costs.

Mon–Sat 7:00am–7:00pm · Licensed & insured · Serving Tampa, Brandon, Riverview & Wesley Chapel

Tap to call Free quote